Z-PC CANopen Series is an I/O distributed system based on IEC 61131 programming that doesn’t require the use of couplers, controllers or repeaters for each communication line. All modules have a CAN interface with communication speed up to 1 Mbps. These are suitable for signals acquisition and management of plant and machinery where I/Os, compared to controllers, are located in various parts of the plant. All modules support the CANopen communication bus and/or terminals as well as an extensive range of power supply.
Digital I/O Modules
ZC-24DI
24 CH digital input CANopen / ModBUS RS485
ZC-24DI is used to interface N.24 digital signals (PUSH BUTTON, LIMIT SWITCH, REMOTE, CONTROL SWITCH, RELAIS etc.) with all of control systems which are able to communicate by the protocols CANopen or ModBUS RTU (protocol selectable through dip-switch)
ZC-24DO
24 CH digital output CANopen / ModBUS RS485
ZC-24DO is used to drive N.24 MOSFETS from all of the control systems which are able to communicate by the protocols CANopen or ModBUS RTU (protocol selectable through dip-switch).
ZC-16DI-8DO
16 CH digital input - 8 CH digital output CANopen / ModBUS RS485
The ZC-16DI-8DO is an 16 CH input / 8 CH output mixed module. The inputs have 32-bit counters / 10 kHz max frequency, mosfet Outputs with shared negative pole.
Analog I/O Modules
ZC-8AI
8 CH analog input (mA, V) CANopen module
ZC-8AI is used to interface analog inputs (Voltage or current, also with bipolar range) with the CANopen system.
ZC-3AO
3 CH analog output (mA, V) CANopen module
ZC-3AO is used to get N.3 analogue outputs (mA or V) from a CANopen system.
ZC-4RTD
4 Ch RTD (Pt100, Ni100, Pt500, Pt1000) input CANopen module
ZC-4RTD is an interface for RTD sensors (PT100, PT1000, PT500, Ni100) with 2,3 or 4 wires.
ZC-8TC
8 CH Thermocouple (J,K,E,N,S,R,B,T) CANopen module
ZC-8TC is an interface for Thermocouple sensors (J, K, E, N, S, R, B ,T) and generic sensor with mV as standard output signal.
ZC-SG
1 CH strain gauge CANopen module
ZC-SG is a strain gauge signal converter. Measurements taken using the 6-wires or 4-wires technique are available through CANopen protocol.